Fume Hoods

Laboratory Fume Hoods

The laboratory fume hood is first and foremost a safety device. Fume hood selection, placement, and system design is a critical part of the lab planning process. Traxle has over 20 years of experience in fume hood systems design and installation.

IMG_0556Fume Hood Sizes:

Chemical Fume Hoods are manufactured in the traditional sizes listed below. Traxle also offers an 84” fume hood. While the lengths of the hoods are standardized the depths and heights are more flexible. Contact us for more information and pricing on custom sized hoods that meet your specific requirements.

  • 48 inches
  • 60 inches
  • 72 inches
  • 96 inches

Fume Hood Types:

OLYMPUS DIGITAL CAMERA

Our benchtop laboratory fume hoods are available in specific types that fit well with the different HVAC systems that exist today. From traditional bypass hoods to energy-saving models we have them all. Traxle also has available walk-in fume hoods that can be built to almost any specification.

  • Bypass
  • Low Flow
  • Constant Volume
  • Walk-in
  • Polypropylene ( Metal Free )
  • Custom Depths & Widths Available

Fume Hood Accessories:

voltaix 017-w400pxIt is important when purchasing a laboratory fume hood that you carefully review all of the options that are available. If you will be using different gases in the hood we will need to know each type so that the proper valve assembly can be supplied. Contact us so we can walk you through all of the options.

  • Up to 4 electrical outlets per hood
  • Polypropylene liner
  • Up to 8 fixtures per hood (water & gases)
  • Epoxy coated fixtures
  • Airflow monitor
  • Sash Stops (safety & energy savings)
  • Cup sinks or standard sink sizes
  • Ceiling enclosure panels
  • Explosion proof light
  • Access ports
  • Combination and horizontal sashes
  • Distillation Racks
  • Blowers & ductwork

Fume Hood Services:

We have been selling, installing and repairing lab hoods for over 20 years. The selection and installation of a fume hood requires careful planning. There are many factors to consider. Where the laboratory fume hood is placed in the laboratory can be critical to its performance. Call us to assist you with this process.

  • Fume Hood System Design
  • Fume Hood Repair
  • Complete system installation
  • Inspection of existing systems to ensure proper performance.
  • Airflow monitor installation on existing hoods.
  • SEFA-1 Testing

Serving NJ, NY, Long Island, New York State, CT, DE, PA, including Philadelphia, Princeton, New Brunswick, Allentown, PA, Bergen County, Passaic County, Essex County, Union County, Somerset County, Middlesex County, Monmouth County, and more.